FREE SHIPPING on eligible items when you order $24.50 or more! (48 Contiguous States)

Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit

Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit
Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit

About

Westcoat EC-34 Epoxy Topcoat is a two-component, 100% solids, medium viscosity, low odor, high-build, chemical resistant epoxy.

Specs

  • Coverages:
    • ~300-500 ft2 / US gal. (as a primer)
    • ~100-300 ft2 / US gal. (as a coating)
  • VOC Content: 0 g/l
  • Mix Ratio: 2:1 (by volume)

    Instructions

    Inspection

    • The surface must be structurally sound, clean, dry, and free of grease, paint, oil, dust, curing agents, laitance or any foreign material that will prevent proper adhesion.
    • The concrete should be at least 2,500 PSI and porous or rough enough to allow the product to soak in.
    • A minimum of 28 days curing time is required on all concrete.
    • Prior to starting work, test existing concrete slab for efflorescence, moisture and hydrostatic pressure.


    Preparation

    • Pre-cut and clean all cracks and joints with a concrete diamond blade to at least 1/4 x 1/4 inch.
    • Prepare concrete to a profile equal to CSP 3-4 as specified by ICRI.
    • Methods may vary according to the condition and hardness of the concrete.
    • Other factors include the forecasted use of the surface and the environment in which it is to be installed.
    • When preparing the surface use caution when shot blasting, scarifying too aggressively, leaving grind marks or grinding too smooth.
    • Please refer to desired System Specification Sheet for more information on preparation.


    Moisture

    • All concrete should be tested for moisture before applying a seamless coating.
    • If moisture emissions exceed 5 lbs/1000 square feet/24 hours (ASTM F1869) or if the relative humidity (RH) exceeds 75% (ASTM F2170), contact the manufacturer before application.


    Mixing

    • Premix each component separately.
    • For color consistency, box all part A's.
    • In a clean bucket, mix 2 parts A with 1 part B (by volume) of EC-34.
    • Mix thoroughly with a low speed (400-600 rpm) drill motor for 3-4 minutes.
    • Make sure to scrape the sides and bottom of the container during mixing.
    • After mixing is completed, remove material from container within 5 minutes, as epoxy will begin to generate heat.
    • Spread immediately onto the floor. As product is spread out, you will have longer working time (10-15 minutes at 70°F).


    Thinning

    • EC-34 can be thinned with up to 10-20% CA-23 or acetone, by volume.
    • If thinned, it must be applied thinly enough to allow solvent to escape (minimum 300 square feet per gallon).
    • As a primer: EC-34 may be thinned with up to 100% CA-23 or acetone.
    • As a coating: EC-34 may be thinned with 10-20% CA-23 or acetone.


    Coverage

    • Coverage will vary depending on condition of surface and desired thickness.
    • As a primer: 300-500 square feet per gallon.
    • As a coating: 100-300 square feet per gallon.


    Applying Product

    • As a primer:
      • Spray or squeegee and backroll thinned EC-34 onto the surface.
      • Primer coat should be applied evenly and worked into the surface to help seal and avoid pinholes.
      • When thinned, apply EC-34 at a maximum of 5 mils.
      • Do not allow material to puddle.
    • As a coating:
      • Apply EC-34 within 24 hours after the primer coat.
      • Immediately after mixing, spread a strip of material onto the surface along the edges where it will be "cut in" using a brush.
      • Pour the remaining material near the "cut in" area and spread evenly using a trowel or squeegee and back roll using a 1/4" to 3/8" nap, non-shedding roller.
      • A notched trowel or squeegee will help regulate the thickness and a porcupine roller will help to release trapped air and minimize bubbles.
      • Depending on the look, thickness, chemical, and abrasion resistance desired, 1 to 2 coats may be applied.
      • Please refer to desired System Specification Sheet for more information on applying the product.


    Dry Time

    • You may re-coat as soon as the surface is dry to touch or in about 9-10 hours.
    • Light foot traffic may be permitted in 12 hours, normal traffic in 24 hours and vehicle traffic in 3 days.
    • All times are based on average temperature of 70°F and 50% humidity.
    • Cooler temperatures will increase drying time.


    Clean Up

    • Uncured material should be removed with an environmentally-safe solvent.
    • Cured material should be removed mechanically.


    Limitations

    • This product is designed for professional use only.
    • Be sure to measure and mix properly. Be aware of the pot life of mixed epoxy.
    • Do not apply when temperatures are below 50°F or above 90°F. Hot or cold weather will affect dry times.
    • Epoxy must be cured for a minimum of 24 hours before coming in contact with water.
    • Skid resistant additives are available, such as CA-30 or CA-31.
    • For interior use only unless protected by a UV resistant coating.
    • Solvents may be required in cooler weather or lower viscosity and increase coverage of 100% solids.
    • Please check with local laws governing the use of solvents.
    • Do not allow Westcoat products to freeze.
    See More

    Westcoat EC-34 100% Solids Pigmented Epoxy Topcoat | 1.5 Gallon Kit

    Quantity must be 1 or more
    Color
    Regular price
    $228.95
    Sale price
    $228.95

    EC-34 epoxy is used to create industrial seamless floors in manufacturing plants, mechanical warehouses, industrial kitchens and garages. It is best used as a filler coat, broadcast coat, or topcoat.

    Special Order Colors
    Tile Red, Safety Red, Safety Yellow, Safety Blue, and Safety Green require up to 10 business days for production as they are made to order.

    Color will vary between products and sheens. Colors are for reference only. Please request an actual color sample or apply sample on site before beginning any project.

    • High strength
    • Superior adhesion resistance
    • Convenient 2:1 mix
    • USDA/FDA compliant

    Attention: Material is considered hazmat, and cannot be shipped air.

    About

    Westcoat EC-34 Epoxy Topcoat is a two-component, 100% solids, medium viscosity, low odor, high-build, chemical resistant epoxy.

    Specs

    • Coverages:
      • ~300-500 ft2 / US gal. (as a primer)
      • ~100-300 ft2 / US gal. (as a coating)
    • VOC Content: 0 g/l
    • Mix Ratio: 2:1 (by volume)

      Instructions

      Inspection

      • The surface must be structurally sound, clean, dry, and free of grease, paint, oil, dust, curing agents, laitance or any foreign material that will prevent proper adhesion.
      • The concrete should be at least 2,500 PSI and porous or rough enough to allow the product to soak in.
      • A minimum of 28 days curing time is required on all concrete.
      • Prior to starting work, test existing concrete slab for efflorescence, moisture and hydrostatic pressure.


      Preparation

      • Pre-cut and clean all cracks and joints with a concrete diamond blade to at least 1/4 x 1/4 inch.
      • Prepare concrete to a profile equal to CSP 3-4 as specified by ICRI.
      • Methods may vary according to the condition and hardness of the concrete.
      • Other factors include the forecasted use of the surface and the environment in which it is to be installed.
      • When preparing the surface use caution when shot blasting, scarifying too aggressively, leaving grind marks or grinding too smooth.
      • Please refer to desired System Specification Sheet for more information on preparation.


      Moisture

      • All concrete should be tested for moisture before applying a seamless coating.
      • If moisture emissions exceed 5 lbs/1000 square feet/24 hours (ASTM F1869) or if the relative humidity (RH) exceeds 75% (ASTM F2170), contact the manufacturer before application.


      Mixing

      • Premix each component separately.
      • For color consistency, box all part A's.
      • In a clean bucket, mix 2 parts A with 1 part B (by volume) of EC-34.
      • Mix thoroughly with a low speed (400-600 rpm) drill motor for 3-4 minutes.
      • Make sure to scrape the sides and bottom of the container during mixing.
      • After mixing is completed, remove material from container within 5 minutes, as epoxy will begin to generate heat.
      • Spread immediately onto the floor. As product is spread out, you will have longer working time (10-15 minutes at 70°F).


      Thinning

      • EC-34 can be thinned with up to 10-20% CA-23 or acetone, by volume.
      • If thinned, it must be applied thinly enough to allow solvent to escape (minimum 300 square feet per gallon).
      • As a primer: EC-34 may be thinned with up to 100% CA-23 or acetone.
      • As a coating: EC-34 may be thinned with 10-20% CA-23 or acetone.


      Coverage

      • Coverage will vary depending on condition of surface and desired thickness.
      • As a primer: 300-500 square feet per gallon.
      • As a coating: 100-300 square feet per gallon.


      Applying Product

      • As a primer:
        • Spray or squeegee and backroll thinned EC-34 onto the surface.
        • Primer coat should be applied evenly and worked into the surface to help seal and avoid pinholes.
        • When thinned, apply EC-34 at a maximum of 5 mils.
        • Do not allow material to puddle.
      • As a coating:
        • Apply EC-34 within 24 hours after the primer coat.
        • Immediately after mixing, spread a strip of material onto the surface along the edges where it will be "cut in" using a brush.
        • Pour the remaining material near the "cut in" area and spread evenly using a trowel or squeegee and back roll using a 1/4" to 3/8" nap, non-shedding roller.
        • A notched trowel or squeegee will help regulate the thickness and a porcupine roller will help to release trapped air and minimize bubbles.
        • Depending on the look, thickness, chemical, and abrasion resistance desired, 1 to 2 coats may be applied.
        • Please refer to desired System Specification Sheet for more information on applying the product.


      Dry Time

      • You may re-coat as soon as the surface is dry to touch or in about 9-10 hours.
      • Light foot traffic may be permitted in 12 hours, normal traffic in 24 hours and vehicle traffic in 3 days.
      • All times are based on average temperature of 70°F and 50% humidity.
      • Cooler temperatures will increase drying time.


      Clean Up

      • Uncured material should be removed with an environmentally-safe solvent.
      • Cured material should be removed mechanically.


      Limitations

      • This product is designed for professional use only.
      • Be sure to measure and mix properly. Be aware of the pot life of mixed epoxy.
      • Do not apply when temperatures are below 50°F or above 90°F. Hot or cold weather will affect dry times.
      • Epoxy must be cured for a minimum of 24 hours before coming in contact with water.
      • Skid resistant additives are available, such as CA-30 or CA-31.
      • For interior use only unless protected by a UV resistant coating.
      • Solvents may be required in cooler weather or lower viscosity and increase coverage of 100% solids.
      • Please check with local laws governing the use of solvents.
      • Do not allow Westcoat products to freeze.